Federal Pacific, Zinsco, Fuse Boxes and Aluminum Wiring in Rockford Homes

Updated

Get a free quote

We reply with a price. Nothing is booked until you say yes.

Rather talk? Call (815) 420-4652 or text us.

Short answer

Part of Electrical Panel Upgrade.

Federal Pacific Stab-Lok

Federal Pacific Electric panels with Stab-Lok breakers were installed widely from the 1950s into the 1980s. You can usually spot one by the name "Federal Pacific" or "FPE" on the door and "Stab-Lok" on the label, with thin breakers that have a red or black stripe. In 1983 the U.S. Consumer Product Safety Commission closed a two-year investigation of the breakers, saying the data available did not establish that they posed a serious risk of injury. In 2011 it revised that release with a note asking electricians, home inspectors and real estate agents to read it carefully (CPSC). In other words: not a recall, and not a clean bill of health. Many insurers ask about these panels, and replacing one is a common condition of a home sale.

Zinsco

Zinsco panels, often with multi-colored breakers, were common in the 1960s and 1970s. They are another frequent home-inspection flag because their breakers can stick or the bus bars can deteriorate. No CPSC action like the FPE investigation was found; the concern comes from field reports and inspectors. Replacement is a standard panel replacement.

Fuse boxes

Screw-in fuse boxes were standard in houses wired before the mid-1950s, often on 60-amp services. The fuses themselves still work. The trouble is what people do to them: a 30-amp fuse screwed into a 15-amp circuit so it stops blowing, which lets the wire overheat before the fuse does. A fuse box also usually means an old service, two-prong outlets and sometimes knob-and-tube wiring upstream.

Aluminum branch wiring (1965 to 1973)

During a copper shortage, an estimated 2 million American homes were built with aluminum branch-circuit wiring between 1965 and 1973 (CPSC). A survey done for the CPSC found that homes built before 1972 and wired with aluminum were 55 times more likely than copper-wired homes to have one or more connections reach "fire hazard conditions" (CPSC Publication 516). The CPSC's warning signs are cover plates that are warm to the touch, a smell of burning plastic, and flickering lights. Its recommended permanent repairs are rewiring with copper or connecting copper pigtails with special listed connectors, not twist-on connectors alone.

How many Rockford houses are in those years

The Census Bureau doesn't count panels or wire. It does count age: in the City of Rockford, 46.5% of housing units were built before 1960 and 27.7% between 1960 and 1979, against a county median build year of 1971 (Census Bureau). Many of those houses have been updated since. The only way to know what is in yours is to open the panel cover, look at the brand and the wire, and have an electrician check it.

What to do

  • Find the brand on the panel door and label, and photograph it.
  • Look for silver-colored wire at a few outlets with the power off (aluminum is dull silver; copper is orange-brown).
  • If you are buying, ask the inspector to note the panel brand and the branch wiring.
  • Get a price on replacement; the permit and inspection come with it in Rockford.

Want a price for your own home?

Call, text, or send the form with what you need done and the panel size if you know it. You get a written price before any work starts.

Quick answers

Is a Federal Pacific panel dangerous?

The CPSC closed its 1983 investigation saying its data did not establish a serious risk, and it never recalled them. It did not declare them safe either, and many electricians and insurers recommend replacement.

Was Federal Pacific recalled?

No federal recall was issued. The CPSC closed its investigation in 1983 and revised the release in 2011 with a note asking readers to interpret it carefully.

Is aluminum wiring dangerous?

The CPSC says pre-1972 homes wired with aluminum are 55 times more likely to have a connection reach fire-hazard conditions than copper-wired homes. Repairs with listed connectors or rewiring fix it.

Do I have to replace a fuse box?

No Illinois rule requires it in an existing house. Insurers, buyers and new loads usually force the issue. Fuses must be the right size for the wire.

How much does it cost to replace an old panel?

Typical U.S. ranges run $1,500 to $4,000 for a 200-amp panel replacement and $2,500 to $6,000 if the service is upgraded too. See the cost page.